TE-6070

PM10 Mass Flow Controlled Systems

Mass Flow Controlled PM10 System. Includes size selective inlet (<10 micron cut size), anodized aluminum shelter, 8” x 10” stainless steel filter holder with probe hole, blower motor assembly, continuous flow/pressure recorder, elapsed time indicator, filter media holder/filter paper cartridge, mass flow controller with 20-60 scfm air flow probe, 7-day mechanical timer. (110V/60hz or 220v/50hz). Meets EPA’s PM10 Code of Federal Regulations Appendix J to Part 50.

 
SPECIFICATIONS
 
 

Flow rate:

40 cfm (adjustable)1.02-1.24m³)
  Filter media: Micro-Quartz filter media 8” x 10” for PM10 (TE-QMA)
  Flow control: Mass Flow Controller w/20-60 SCFM Air Flow Probe (TE-300-310)
  Motor blower: 2-stage vacuum 0.6 HP 110v/60hz (TE-116311) 220v/50hz (TE-116312)
  Timer: 7-day mechincal timer (TE-5007)
     
Shipping Information:
 
 

Size/Weight:

23” x 20” x 46”/65 lbs. 32” x 32” x 25.5” /60
  Start up amps: 12 amps
  Running amps: 4 amps
   
 